The boiler alone is just a heat source. To run safely and efficiently it needs a full set of components between itself and the heating system — the boiler piping kit. Without proper piping, even an expensive boiler short-cycles, overheats and fails early.
The pump is the heart of the heating system. Wet-rotor — in-fluid rotor, quiet, maintenance-free, up to 300 m² (Grundfos UPS, Wilo Star-RS). Dry-rotor — higher efficiency but noisy, for large systems.
For a 100 m² house: head 4–6 m, flow 1.5–2.5 m³/h. Modern models (Grundfos Alpha3, Wilo Yonos PICO) modulate automatically, saving up to 50% electricity. Install on the return before the boiler — cooler fluid extends pump life.
Mixes cooled return into hot boiler supply. The boiler delivers 60–80 °C but underfloor heating needs 35–45 °C. Without the valve, floor pipes overheat and screed breaks down. Thermal head for simple systems, servo-driven for smart-home setups.
Water expands when heated. Without somewhere to go, pressure spikes and the safety valve opens. A membrane tank accommodates the expansion — 10% of total coolant volume. For a 100 m² house (60–80 L coolant) — a 10–12 L tank, mounted on the return before the pump, air chamber up.
Mandatory in closed systems. Three devices on one manifold: pressure gauge (norm 1.0–2.0 bar), auto air vent, safety valve (opens at 3 bar). Installed on the supply line at the boiler outlet. Never place a shut-off valve between the boiler and the safety group.
Ball valves at every component — isolate for service without draining
Strainers before pump and boiler — catch scale and rust, clean once a year
Needed with multiple loops of different flow rates (radiators, underfloor, indirect cylinder). Without it, loops steal flow from each other. A vertical vessel connects boiler supply/return and all consumer loops; flow slows, pressure equalises, each loop gets exactly what it needs.
When required:
Two or more loops with their own pumps
Boiler power above 50 kW
Flow difference between loops more than 2×
For 80–120 m² houses with one radiator loop and one underfloor loop, a separator is not required — a manifold with a thermal valve is enough.
Boiler supply → safety group → manifold / radiators
Return → strainer → circulation pump → expansion tank (branch) → boiler
Ball valves at every component
Wall-hung boilers with built-in pump and tank simplify the kit: safety group, filter and valves remain external.
No strainer before the boiler — exchanger clogs in 1–2 seasons, 15 000–25 000 ₽ repair
Expansion tank on supply instead of return — faster membrane wear
Shut-off valve between boiler and safety group — dangerous
Undersized expansion tank — safety valve keeps opening
No drain valve — servicing becomes a nightmare
Item | Spec | ₽ |
|---|---|---|
Circulation pump | Grundfos UPS 25-60 / Wilo Star-RS 25/6 | 9 000–16 000 |
Energy-saving pump | Grundfos Alpha3 25-60 | 22 000–28 000 |
Three-way valve | Esbe VRG131 DN20 with thermal head | 7 500–12 000 |
Expansion tank | 12 L, membrane (Flamco, Wester) | 2 500–4 500 |
Safety group | 1/2" or 3/4", 3 bar | 1 800–3 500 |
Hydraulic separator | up to 50 kW, steel | 5 000–12 000 |
Strainer | 3/4", brass | 800–1 500 |
Ball valves (set) | 6–8 pcs, 3/4" | 3 000–5 000 |
Fittings, pipes, seals | kit | 3 000–6 000 |
Installation labour | specialist | 15 000–30 000 |
Total (ex boiler) | 48 000–115 000 |
StroyInvest24 designs and installs boiler rooms across the Leningrad Region to full safety standards, with a workmanship warranty.
Need a consultation on your project? Leave a request: Gas boiler installation.
Get in touch — we'll answer all your questions and help you choose.
Leave a request — we'll contact you, clarify details and offer the best solution for your plot and budget.
Response within 30 minutes
+7921-76-76-76-1
info.stroyinvest24@gmail.com
We'll call back and consult for free