Supply-exhaust ventilation with heat recovery, split systems, multi-split and ducted AC for country houses. Up to 90% heat recovery, heating savings. Serving all of Leningrad Region.
Engineer visits site, determines room volumes, number of residents, kitchen type, bathrooms. Calculate required air exchange per building codes.
Develop ventilation scheme: select supply-exhaust unit with recuperator, design ductwork network, determine grille and diffuser locations.
Install ventilation unit with plate or rotary recuperator (up to 90% heat recovery). Place in utility room, attic or basement.
Install galvanized steel or flexible silenced ducts. Insulate sections in attic and unheated areas to prevent condensation.
Install supply and exhaust grilles in each room. Use adjustable diffusers for precise airflow control in every room.
Install split systems, multi-split or ducted AC. Route refrigerant lines, drainage, connect power. Vacuum the system.
Start system, measure airflow at each grille, balance ducts with dampers, configure automation and timers. Check noise levels.

Installation prices excluding equipment cost. Exact estimate after engineer visit.
HRV unit installation, ductwork and electrical connections
Duct installation, insulation, grilles and diffusers throughout the house
Single split AC: indoor and outdoor unit, refrigerant line, drainage
One outdoor + 2–4 indoor units, refrigerant lines, drainage, commissioning
Full package: HRV unit + ductwork + grilles + balancing
Leave a request — we'll contact you, clarify details and offer the best solution for your plot and budget.
Response within 30 minutes
+7 (921) 767-67-61
info.stroyinvest24@gmail.com
We'll call back and consult for free